Skip to content
Alex Power Technology
Operation

5 reasons for a poor wire-cut finish

6 min readAlex Power technical team

  1. High water conductivity — change the resin.
  2. Worn guide — inspect it with a loupe.
  3. Low wire tension.
  4. Worn power feed contact.
  5. Poor or damp wire.
Share: